Gas Sensor Housing (GSH4) for Flameproof Fixed Gas Detectors
ATEX and IECEx Ex’d Certified Housing
Overview
Features & Benefits
Specifications
Overview
These flameproof gas sensor heads that can be fitted with a range of different sensor technologies (infrared, pellistor, electrochemical) for detection of a wide variety of gasses, depending on the sensor fitted.
They are Ex d certified components and as such must be fitted into compatible separately certified apparatus such a Flameproof (Ex d) junction box, Increased Safety (Ex e) junction box or Flameproof (Ex d) gas detector instrument housing.
Notes:
- The temperature ranges stated here refer to the GSH4 Ex’d sensor housing only. Refer to the relevant sensor data sheet for the sensor specifications.
- When the data communications facility is not required, the ends of the brown and orange wires should be insulated and secured to prevent electrical contact with any other wires or metalwork.
Features & Benefits
- Stainless steel construction with tamperproof protection
- For use with suitable separately certified industry standard junction boxes or OEM gas detector enclosures
- Compact Size
- Various mounting threads available M20, ½” NPT, ¾” NPT
- Can be fitted with a range of different sensor technologies (Infrared, Catalytic (Pellistor) or Electrochemical)
- Range of accessories available for gas application and environmental protection
Specifications
Type | Exd Certified Flameproof sensor housing. |
Material | Stainless Steel grade 303, (Grade 316 available at additional cost) |
Body Dimensions | 40 mm Diameter x 60 mm Long (excluding a thread length of up to 20mm) |
Weights (approx.) | 280 grams |
Operating Temperature | -20ºC to +60ºC See note 1 below. |
Storage Temp | -20ºC to +60ºC See note 1 below. |
Humidity Range | 0 to 95% R.H. Non-condensing |
Sensor Supply Voltage | Dependent upon sensor type |
Electrical Output | Dependent upon sensor type |
Gas Type | Dependent upon sensor type |
Sensor Type | Electrochemical NDIR Infrared Pellistor (catalytic bead) |
Measuring Range | Dependent upon sensor type |
Response Time | Dependent upon sensor type |
Hazardous Area Certification | |
Atex | Sira 10ATEX1358X II 2 G Ex db IIC T4 Gb (Tamb = -20°C to 60°C), EN60079-0:2012+A11 :2013, EN60079-1:2014 |
IECEx | IECEx SIR 10.0184X Ex db llC T4 Gb (Tamb = -20°C to 60°C) IEC 60079-0 :2011 Edition 6.0, IEC 60079-1 :2014-06 Edition 7 |
Ambient Temperature | -20 to +60 O C (T4) (See note 1) |
Zones | 1 & 2 |