DumoPro is a powerful tool for measuring dust concentration in industrial environments because of its high sensitivity to total suspended particles. The field-proven state-of-the-art measurement technology is tolerant to sensor contamination making it reliable in a wide variety of dust detection applications. DumoPro utilizes the Sintrol Inductive Electrification technology providing a wide measuring range.
How?
The Auto Setup function is a unique Sintrol Dust Monitor feature that allows for a simple user-friendly setup.
DumoPro can be managed and parameterized with the DustTool PC Software.
The underlying method is called “optical forward scattering”.
Why?
- The robustness of DumoPro makes it a safe choice for dust monitoring in rugged industrial environments.
- Ideal for flour and sugar mills, mining, wood products, grain handling, chemical plants, power plants, and other bulk and powder handling facilities.
- Detects small particulates accurately.
- Maintains accuracy despite sensor contamination.
- Suitable for health and hygiene, equipment safety, housekeeping, dust explosion risk mitigation, hazardous location monitoring, and detection of unwanted events.
- Auto Setup function simplifies initial setup.
- Enhances user-friendliness and simplifies management processes.
- Durable in demanding industrial conditions.
- Capable of detecting various dust levels.
- Requires minimal maintenance.
- Facilitates connection, tracking, management, and control of multiple dust monitors.
- Offers real-time views of dust levels.
- Provides data storage and reporting capabilities.
Features:
- Continuous real-time dust monitoring in industrial environments
- Low maintenance and robust
- Easy start-up and commissioning
- Wide measurement range
- Internal self-monitoring for failsafe operation
- Fast response time
- No sample handling required
- DumoPro Ex is suitable for zones 20, 21 and 22
Benefits:
- Early detection of dust events
- Workplace dust monitoring
- Equipment and worker protection
- Supports good housekeeping practice
- Helps mitigate the risk of dust explosion
- Product loss prevention
- Long term low maintenance dust monitoring
- Can be used in hazardous locations
Measurement objects: Total Suspended Particles (TSP)
Measurement range: Detection Limit 0.1 mg/m³ Maximum Range up to several g/m³
Measurement principle: Inductive Electrification
Protection code: IP66
Power supply: 24 V DC + – 20%
Power consumption: Up to 10 W
Output signals:
- Two configurable alarm outputs (100 mA @24 V DC)
- Isolated 4 – 20 mA output loop, up to 250 Ω loop resistance, Namur NE43 compliant alarms
Communication interface: Serial communication RS485, USB
Communication protocol:
- Modbus RTU (RS-485)
- Sintrol network (USB and RS-485)
Alarm settings: Set by Auto Setup based on average measured dust level: 5 times and 20 times of reference dust level. User adjustable
Signal averaging time: Default at factory: 100 s, Adjustable from 0-6000 s.
Alarm delay time: Default at factory: 30 s, Adjustable from 0-60 000 s.
Alarm hysteresis time: Default at factory: 0 s, Adjustable from 0-25 s.
AMBIENT CONDITIONS
Running temperature: -40°C to +60 °C (-40 °F to 140 °F)
Humidity: Max 95 % RH (non-condensing)
MATERIALS AND DIMENSIONS
Weight: 4.2 kg (9.3 lbs)
Enclosure / housing: Aluminum enclosure, stainless steel cover plates and probe (AISI 316L).
Dimensions (mm): 288 (L) x 191 (W) x 174 (H)
Ordering infomation:
- PC901600 DumoPro
- PC901080 DumoPro Ex
Options:
- MC900222 Installation Bracket
- MC900237 Installation Arm
- FC900047 DumoPro Adapter M16 Male thread to 1/2″ NPT female thread (HazLoc)
- FC900162 ATEX/IEC Cable Gland for DumoPro Ex
- PC900091 Sintrol Network Router & DustLog Software
Hazardous Location Approvals DumoPro Ex:
- IEC/ATEX: II 1 D Ex ia ta IIIC T200 93°C Da Tamb -30°C to +60°C
- US: Zone 20 AEx ia ta IIIC T93°C Da Ta = -30°C to +60°C
- CAN: Ex ia ta IIIC T93°C Da Ta = -30°C to +60°C