IR-3000C: Converting Products
Series online NIR sensor for instant, non-contact measurement of the Converting and Paper Industry in the most demanding manufacturing environments. Often converting process efficiency is affected by variations in coat weight, inefficient moisture control, thickness, or temperature issues. Provides continuous, reliable readings and is a one-time calibration, maintenance free process adjustments based on real-time measurements. Allowing installation in the most extreme locations. MoisTech’s advanced digital processing, only provides true data for all your converting applications.
Why?
IR-3000C sensor to precisely measure moisture, coat weight, thickness and temperature in converting applications such as paper, films, foils, composite board, hot melts, glues, recycled paper, wax and vinyl coating, resin and many more.
Maintaining the ideal thickness or coat weight int he production line can mean the difference between a quality product your customers or wasted effort and material. Many basic properties of paper are greatly affected by its moisture content. Its dimensions, flatness, conductivity, strength and fold are among the more significant properties influenced by its moisture content.
Pre-calibrated to your application without calibration drifting
Optical window contamination alarm/monitor
Insensitive to ambient temperatures & lights
Store up to|50 different product codes/calibrations
Windows operating software for management & control
3 x 4-20ma outputs available
0-10v available
Sapphire, kel-f, & quartz sensor window options
Optional explosion proof enclosure
- Measured NIR Constituents: 1, 2 or 3
- Moisture Ranges: 0–0.1%, 0–100% PPM Ranges Subject toApplication
- Accuracy (subject to application): ±0.01%
- Repeatability: ±0.01%
- Optical Measurement Distance: 4–16 in (10–40 cm)
- Sampling Size: Approximately 1.5-in (3.7 cm) diameter on sample
- Calibration Codes: 50 Standard
- Enclosure: Cast Aluminum, IP65 (NEMA 4) & Optional IP67 Stainless
- Power: 80–260 VAC (50/60 HZ), Optional 24VDC
Operating Temperature: 0–130°F (0–55°C)
Vortec Cooling (High Temp): Max 170°F (85°C)
Stainless Steel IP67: Max 200F (93C)
- Calibration: Factory Pre-Calibrated, PC Calibration software included, Routine re-calibration is not required
- Ambient Light Sensitivity: None
- Sensor Input/Outputs: Three self-powered isolated 4-20mA outputs, RS-232/485, Ethernet TCP/IP
- Optional interfaces: Profibus, Profinet, DeviceNet, Ethernet IP