Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/sensorsph/public_html/wp-includes/functions.php on line 6121
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
Warning: Cannot modify header information - headers already sent by (output started at /home/sensorsph/public_html/wp-includes/functions.php:6121) in /home/sensorsph/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1896
{"id":7137,"date":"2023-12-23T04:15:49","date_gmt":"2023-12-23T04:15:49","guid":{"rendered":"https:\/\/sensors.ph\/?p=7137"},"modified":"2025-02-27T02:07:11","modified_gmt":"2025-02-27T02:07:11","slug":"exo-dust-monitor-for-wet-gases","status":"publish","type":"post","link":"https:\/\/sensors.ph\/exo-dust-monitor-for-wet-gases\/","title":{"rendered":"Exo Dust Monitor for Wet Gases"},"content":{"rendered":"\t\t
DumoPro is a powerful tool for measuring dust concentration in industrial environments because of its high sensitivity to total suspended particles. The field-proven state-of-the-art measurement technology is tolerant to sensor contamination making it reliable in a wide variety of dust detection applications. DumoPro utilizes the Sintrol Inductive Electrification technology providing a wide measuring range.<\/span><\/p><\/div><\/div><\/div>
How?<\/strong><\/span><\/p>
The Auto Setup function is a unique Sintrol Dust Monitor feature that allows for a simple user-friendly setup.<\/span><\/p><\/div><\/li>
DumoPro can be managed and parameterized with the DustTool PC Software.\u00a0<\/span><\/p><\/div><\/li>
The underlying method is called \u201coptical forward scattering\u201d.<\/span><\/p><\/div><\/li><\/ul>
\u00a0<\/span><\/div>
Why?<\/strong><\/span><\/p>
The robustness of DumoPro makes it a safe choice for dust monitoring in rugged industrial environments.<\/span><\/li>
Ideal for flour and sugar mills, mining, wood products, grain handling, chemical plants, power plants, and other bulk and powder handling facilities.<\/li>
Suitable for health and hygiene, equipment safety, housekeeping, dust explosion risk mitigation, hazardous location monitoring, and detection of unwanted events.<\/li>
Auto Setup function simplifies initial setup.<\/li>
Enhances user-friendliness and simplifies management processes.<\/li>
Durable in demanding industrial conditions.<\/li>
Capable of detecting various dust levels.<\/li>
Requires minimal maintenance.<\/li>
Facilitates connection, tracking, management, and control of multiple dust monitors.<\/li>
Offers real-time views of dust levels.<\/li>
Provides data storage and reporting capabilities.<\/li><\/ul><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div>\n\t\t\t\t\t\t\t\t\t
Features & Benefits<\/div>\n\t\t\t\t\t
Features:<\/strong><\/p>
Continuous real-time dust monitoring in industrial environments<\/li>
Low maintenance and robust<\/li>
Easy start-up and commissioning<\/li>
Wide measurement range<\/li>
Internal self-monitoring for failsafe operation<\/li>
Fast response time<\/li>
No sample handling required<\/li>
DumoPro Ex is suitable for zones 20, 21 and 22<\/li><\/ul>
Benefits:<\/strong>\u00a0<\/p>
Early detection of dust events<\/li>
Workplace dust monitoring<\/li>
Equipment and worker protection<\/li>
Supports good housekeeping practice<\/li>
Helps mitigate the risk of dust explosion<\/li>
Product loss prevention<\/li>
Long term low maintenance dust monitoring<\/li>
Can be used in hazardous locations<\/li><\/ul><\/div>\n\t\t\t\t\t\t\t\t\t
Specifications<\/div>\n\t\t\t\t\t
Measurement objects:<\/strong> Total Suspended Particles (TSP)<\/p>
Measurement range:<\/strong> Detection Limit 0.1 mg\/m\u00b3 Maximum Range up to several g\/m\u00b3<\/p>
Measurement principle:<\/strong> Inductive Electrification Protection code:<\/strong> IP66 Power supply:<\/strong> 24 V DC + – 20% Power consumption:<\/strong> Up to 10 W Output signals:<\/strong><\/p>
Two configurable alarm outputs (100 mA @24 V DC)<\/li>
Isolated 4 – 20 mA output loop, up to 250 \u2126 loop resistance, Namur NE43 compliant alarms<\/li><\/ul>
Communication interface: <\/strong>Serial communication RS485, USB Communication protocol:<\/strong><\/p>
Modbus RTU (RS-485)<\/li>
Sintrol network (USB and RS-485)<\/li><\/ul>
Alarm settings:<\/strong> Set by Auto Setup based on average measured dust level: 5 times and 20 times of reference dust level. User adjustable Signal averaging time:<\/strong> Default at factory: 100 s, Adjustable from 0-6000 s. Alarm delay time<\/strong>: Default at factory: 30 s, Adjustable from 0-60 000 s. Alarm hysteresis time:<\/strong> Default at factory: 0 s, Adjustable from 0-25 s.<\/p>
AMBIENT CONDITIONS<\/strong><\/span><\/p>
Running temperature:\u00a0<\/strong> -40\u00b0C to +60 \u00b0C (-40 \u00b0F to 140 \u00b0F) Humidity:<\/strong> Max 95 % RH (non-condensing)<\/p>
MATERIALS AND DIMENSIONS<\/strong><\/span><\/p>
Weight:<\/strong> 4.2 kg (9.3 lbs) Enclosure \/ housing:<\/strong> Aluminum enclosure, stainless steel cover plates and probe (AISI 316L). Dimensions (mm):<\/strong> 288 (L) x 191 (W) x 174 (H) Ordering infomation:<\/strong><\/p>
PC901600 DumoPro<\/li>
PC901080 DumoPro Ex<\/li><\/ul>
Options: <\/strong><\/p>
MC900222 Installation Bracket<\/li>
MC900237 Installation Arm<\/li>
FC900047 DumoPro Adapter M16 Male thread to 1\/2″ NPT female thread (HazLoc)<\/li>
FC900162 ATEX\/IEC Cable Gland for DumoPro Ex<\/li>
IEC\/ATEX: II 1 D Ex ia ta IIIC T200 93\u00b0C Da Tamb -30\u00b0C to +60\u00b0C<\/li>
US: Zone 20 AEx ia ta IIIC T93\u00b0C Da Ta = -30\u00b0C to +60\u00b0C<\/li>
CAN: Ex ia ta IIIC T93\u00b0C Da Ta = -30\u00b0C to +60\u00b0C<\/li><\/ul><\/div>\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"
Overview Features & Benefits Specifications Overview DumoPro is a powerful tool for measuring dust concentration in industrial environments because of its high sensitivity to total suspended particles. The field-proven state-of-the-art measurement technology is tolerant to sensor contamination making it reliable in a wide variety of dust detection applications. DumoPro utilizes the Sintrol Inductive Electrification technology […]<\/p>\n","protected":false},"author":6,"featured_media":7139,"comment_status":"open","ping_status":"open","sticky":false,"template":"elementor_theme","format":"standard","meta":{"site-sidebar-layout":"default","site-content-layout":"","ast-site-content-layout":"default","site-content-style":"default","site-sidebar-style":"default","ast-global-header-display":"","ast-banner-title-visibility":"","ast-main-header-display":"","ast-hfb-above-header-display":"","ast-hfb-below-header-display":"","ast-hfb-mobile-header-display":"","site-post-title":"","ast-breadcrumbs-content":"","ast-featured-img":"","footer-sml-layout":"","theme-transparent-header-meta":"","adv-header-id-meta":"","stick-header-meta":"","header-above-stick-meta":"","header-main-stick-meta":"","header-below-stick-meta":"","astra-migrate-meta-layouts":"set","ast-page-background-enabled":"default","ast-page-background-meta":{"desktop":{"background-color":"var(--ast-global-color-4)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"ast-content-background-meta":{"desktop":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"tablet":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""},"mobile":{"background-color":"var(--ast-global-color-5)","background-image":"","background-repeat":"repeat","background-position":"center center","background-size":"auto","background-attachment":"scroll","background-type":"","background-media":"","overlay-type":"","overlay-color":"","overlay-gradient":""}},"footnotes":""},"categories":[67,93],"tags":[],"class_list":["post-7137","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ambient-monitoring","category-dust-monitors-for-filter-houses-sintrol"],"yoast_head":"\n
Exo Dust Monitor for Wet Gases - Sensor Suppliers Philippines<\/title>\n\n\n\n\n\n\n\n\n\n\n\n\t\n\t\n\t\n\n\n\n\t\n\t\n\t\n